<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>40811</ErrorNumber>
<ErrorFamily>Media Handler</ErrorFamily>
<ErrorMessage>
MDH: Unable to pull media out of engine.  Media still detected at entry sensor [&lt;I/O name&gt;]
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_ContinuousLoad</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Autoloader</Text></ListItem>
<ListItem><Text>Trendsetter_NEWS</Text></ListItem>
<ListItem><Text>Trendsetter_Series_4</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
During unload, the unload table stepper motor pulls the media out of the engine.  After the pull
is completed, the table entry sensors are checked to make sure the media is fully on the table.  If
a sensor reads True, this error is reported.
</text></DescriptionText>
<DescriptionText><text>
Use the &lt;&lt;table&gt;&gt; command to display the sensor readings.
</text></DescriptionText>
<DescriptionText><text>
It is possible to bypass the sensors using the &lt;&lt;scan&gt;&gt; command.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
A device error has occurred:
</text></DescriptionText>
<DescriptionText><text>
You may be able to continue by pressing the "resume" button onscreen (if present)
or by resetting the device and workstation.
</text></DescriptionText>
<DescriptionText><text>
For support under your service contract, contact the Creo Response Center at 1-(800) 472-2727
or online at http:\\eCentral.creo.com (or your local service representative)
</text></DescriptionText>
<DescriptionText><text>
To speed troubleshooting, please make a note of error numbers, the media type/size
and any information about the workflow or job that might be relevant.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
Stepper motor stalling -
Media binding in leading edge clamps.
</Cause>
<Cause>
Faulty sensor -
The sensor may have been damaged, or there may be something blocking the sensor.
</Cause>
<Cause>
Incorrect NVS parameter "mhauto LECToUnloadHome" -
If the "mhauto LECToUnloadHome" parameter is not set accurately, the unload traveller
may not pull the plate far enough out of the engine to move past the unload table entry
sensor.
</Cause>
<Parameter>
I/O name -
This is the standard firmware name of the sensor that still detects the media.
</Parameter>
<LastModified>
18-Jan-2005
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:31 2008 PST
</Updated>
<Links>
</Links>
</Error>